4. At the ok prompt, type:
ok obdiag
The OBDiag menu is displayed.
Note - The OBDiag menu is built dynamically each time you run the obdiag
command. The exact number and order of menu items in the example might not
match the menu items on your system.
OBDiag Menu
0 ..... PCI/Cheerio
1 ..... EBUS DMA/TCR Registers
2 ..... Ethernet
3 ..... Keyboard
4 ..... Mouse
5 ..... Parallel Port
6 ..... Serial Port A
7 ..... Serial Port B
8 ..... NVRAM
9 ..... Audio
10 ..... SCSI
11 ..... All Above
12 ..... Quit
13 ..... Display this Menu
14 ..... Toggle script-debug
15 ..... Enable External Loopback Tests
16 ..... Disable External Loopback Tests
Enter (0-11 tests, 12 -Quit, 13 -Menu) ===>
5. At the OBDiag menu prompt, type 14 to select toggle script-debug.
Note - Selecting toggle script-debug enables verbose test message displays.
6. At the Enter prompt, type the appropriate test number.
196
Sun Enterprise 220R Server Service Manual January 2000, Revision A