Sun-microsystems SUN BLADETM X6440 Manual de usuario Pagina 28

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 28
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 27
26 Sun Blade X6440 Server Module Product Notes November 2009
LSI RAID Expansion Module (REM)
Issues
This section contains the following LSI RAID REM issues:
“Extra hard disk drive space required when upgrading to a Mirrored RAID
configuration” on page 26
“Upgrade path for data merging” on page 26
Extra hard disk drive space required when
upgrading to a Mirrored RAID configuration
You must have 100 MB of free unpartitioned disk space at the end of the hard disk
drive if you want to upgrade to a mirrored RAID configuration.
Upgrade path for data merging
The only upgrade path that supports data merging is from a single disk to a mirror.
This is a limitation of the LSI card. If you want to upgrade from a single disk to an
IME (Integrated Mirror Extension) or an IMS (Integrated Mirror Stripe), the data and
OS will be lost and a reinstallation and restore will be required.
Vista de pagina 27
1 2 ... 23 24 25 26 27 28

Comentarios a estos manuales

Sin comentarios