Sun-microsystems SUN STOREDGETM 5310 NAS Manual de usuario Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 382
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
1-24 Sun StorEdge 5310 NAS Troubleshooting Guide December 2004
File System Errors
File system error messages occur when the file system usage exceeds a defined usage
threshold. The default usage threshold is 95%.
PEMS Events
Sun StorEdge 5310 NAS employs the PEMS board to monitor environmental systems
and to send messages regarding fan, power supply, and temperature anomalies.
Note – Device locations are shown in the Sun StorEdge 5310 NAS Hardware
Installation, Configuration, and User Guide included in your documentation CD.
Table A-5 describes the PEMS error messages for the Sun StorEdge 5310 NAS.
TABLE A-4 File System Errors
Event E-Mail Subject: Text SNMP Trap LCD Panel Log
File System
Full
File system full:
File system <name> is xx% full.
Action: 1. Delete any unused or
temporary files, OR
2. Extend the partition by using an
unused partition, OR
3. Add additional disk drives and
extend the partition after creating a
new partition.
(Severity=Error)
PartitionFull F40
FileSystemName
full
File system
<name> usage
capacity is xx%.
TABLE A-5 PEMS Error Messages
Event E-Mail Subject: Text SNMP Trap LCD Panel Log
CPU Fan
Error
Fan Failure:
The CPU fan has failed. Fan speed = xx
RPM.
Action: The system will shut down in 10
seconds to protect the CPU from damage.
You should replace the CPU fan before
turning the system back on.
Severity = Critical
envFanFail trap P11 CPU fan
failed
The CPU fan
has failed!
Better shut
down.
Vista de pagina 41