Chapter 1 Setting Up the Server Hardware 15
5. If desired, connect an RJ-45 serial port cable to the “SERIAL MGT” connector.
Note the following considerations for the serial port and serial port cabling:
The default serial port speed is 9600 baud with no flow control.
These servers use the same pinout as the RJ45 port on the RSC/ALOM/ALOM
Plus cards on Sun Netra™ and other Sun Fire systems.
There is a compatible Sun RJ45-to-DB9 adapter shipped with the server, part
number 530-3100.
An alternative, compatible cable is the Cisco 72-3383-01 console cable.
6. Continue with “Powering On and Off the Server” on page 16.