3-14 Sun StorEdge A3500/A3500FC Hardware Configuration Guide December 1999
3.3 1x5 Cables and Connections
This section contains information about SCSI, FC-AL, and power connections for one
StorEdge A3500, or one StorEdge A3500FC controller module, with five StorEdge
D1000 disk arrays.
3.3.1 Driveside SCSI Connections
The following table shows the lengths of each SCSI cable connected to the drive
connections on the controller module.
The inboard IN/OUT connectors on each of the disk arrays are connected using a
0.2m/0.65 ft SCSI jumper cable, part number 530-1883.
The outboard IN/OUT-2 connector on each disk array is terminated with a
differential SCSI terminator, part number 150-1890.
FIGURE 3-15 shows the SCSI connections between the A3500 controller module and
the five D1000 disk arrays.
TABLE 3-7 Controller Module A (1x5) Cables
SCSI Port Number Cable Length Part Number
1 2.0m/6.5 ft 530-1885
2 2.0m/6.5 ft 530-1885
3 2.0m/6.5 ft 530-1885
4 2.0m/6.5 ft 530-1885
5 2.0m/6.5 ft 530-1885