Vista de pagina 135
120 Sun StorEdge 3900 and 6900 Series Troubleshooting Guide March 2002
t3 interface.
loopcard
StateChange- Red Y [ Info/Action ]
Information:
The SunStorEdge T3+
array has indicated
that theloopcard is no
longer in an optimal
state.
Recommended action:
1. Telnet to the
affected Sun
StorEdge T3+
array.
2. Verify loopcard
state with fru
stat
3. Verify matching
firmware with
other loopcard.
4. Re-enable loopcard
if possible (enable
u(encid)|[1|2|]
5. Replace the
loopcard if
necessary.
Category Component EventType Sev Action Description Information