Chapter 7 Troubleshooting Virtualization Engine Devices 75
For Internal Use Only
Fibre Channel Link Error Status Report
The virtualization engine’s host-side and device-side interfaces provide statistical
data for the counts listed in
TABLE 7-4.
TABLE 7-4 Virtualization Engine Statistical Data
Count Type Description
Link Failure Count The number of times the virtualization engine’s frame manager
detects a non-operational state or other failure of N_Port
initialization protocol.
Loss of
Synchronization
Count
The number of times that the virtualization engine detects a loss in
synchronization.
Loss of Signal Count The number of times that the virtualization engine’s frame manager
detects a loss of signal.
Primitive Sequence
Protocol Error
The number of times that the virtualization engine’s frame manager
detects N_Port protocol errors.
Invalid Transmission
Word
The number of times that the virtualization engine’s 8b/10b
decoder does not detect a valid 10-bit code.
Invalid CRC Count The number of times that the virtualization engine receives frames
with a bad CRC and a valid EOF. A valid EOF includes EOFn, EOFt,
or EOFdti.