Sun-microsystems StorEdge 6900 Series Manual de usuario Pagina 137

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 162
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 136
Chapter 8 Troubleshooting the Sun StorEdge T3+ Array Devices 121
For Internal Use Only
t3 volume StateChange- Red Y [ Info/Action ] Information: The Sun
StorEdge T3+ array
has reported that a
power cooling unit
has been disabled.
Recommended action:
1. Check the Sun
StorEdgeT3+array
syslog for battery
hold times.
2. If < 6 minutes,
replace the battery,
or the entire PCU,
as required.
t3 power StateChange- Red Y [
Info/Action ]
power.u1pcu2(TECT
ROL-CAN.300-
1454-
01(50).008275)in
T3 rasd2-t3b1
(ip=xxx.0.0.41)is
now Not-Available
(status-state changed
from ready-enabled to
ready-disable).
Information: The Sun
StorEdge T3+ array
has reported that a
LUN has changed
state.
Recommended action:
1. Telnet to the
affected Sun
StorEdgeT3+array
2. Check the status of
LUNs via vol
mode or vol
stat.
t3 enclosure Statistics Statistics about T3
d2-t3b1
(ip=xxx.0.0.41)
Category Component EventType Sev Action Description Information
Vista de pagina 136
1 2 ... 132 133 134 135 136 137 138 139 140 141 142 ... 161 162

Comentarios a estos manuales

Sin comentarios